<div class="textblock"><h1>VIVANA 4.16.0 (2019-05-06)</h1>
<p>Initial release of <code>VIVANA</code> 4.16.</p>
<h2>VIVANA 4.16.0 Known issues</h2>
<p>No known issues in the 4.16.0 version.</p>
<h2>VIVANA 4.16.0 Input changes</h2>
<p>Input files used in version 4.14 can be used unchanged.</p>
<h2>VIVANA 4.16.0 Removed functionality</h2>
<p>No previously available functionality have been removed in this version.</p>
<h2>VIVANA 4.16.0 Deprecated functionality</h2>
<p>No functionality is deprecated in this version.</p>
<h1>VIVANA licensing</h1>
<p><code>VIVANA</code> is license-managed using the FLEXlm / FLEXlnet software license management system. If you want <code>VIVANA</code> to be used from any networked computer on your site, you must run a license manager on a server in your network. Alternatively, <code>VIVANA</code> may be run on a single computer using a standalone license file.</p>
<p><b>Please note that version 4.2 and higher requires a licence file with a feature version that is equal or larger than the link date.</b></p>
<p>In order to issue a server license or a standalone license file, SINTEF Ocean or DNV GL needs the following info on your server:</p>
<ul>
<li>License type (server or standalone)</li>
<li>Operating system and version (Windows 7, Windows XP, HP-UX and Linux currently supported)</li>
<li>MAC address / FLEXlm hosted of the computer.</li>
</ul>
<p>Your IT-staff is probably already familiar with this procedure as FLEXlm is used by a large number of other applications (e.g. Matlab).</p>
<h1>VIVANA version numbers</h1>
<p>The version number consists of three numbers separated by periods, e.g. 4.16.0. The two first are the version. The third is updated for each subsequent (bug fix) release.</p>
<p>Even numbered versions, e.g. 4.14, 4.16, are reserved for official versions.</p>
<p>Odd numbered versions, e.g. 4.15, 4.17, are reserved for development versions. The next official release will therefore be 4.18.</p>
<h1>VIVANA 4.14.0 (2018-11-01)</h1>
<p>Initial release of <code>VIVANA</code> 4.14.</p>
<h2>VIVANA 4.14.0 Known issues</h2>
<p>No known issues in the 4.14.0 version.</p>
<h2>VIVANA 4.14.0 Input changes</h2>
<p>Input files used in version 4.12 can be used unchanged.</p>
<h2>VIVANA 4.14.0 Removed functionality</h2>
<p>No previously available functionality have been removed in this version.</p>
<h2>VIVANA 4.14.0 Deprecated functionality</h2>
<p>No functionality is deprecated in this version.</p>
<h1>VIVANA 4.12.2</h1>
<h2>VIVANA 4.12.2 Corrected errors</h2>
<h3>User-defined added mass for in-line VIV</h3>
<p>The default in-line added mass curves were used even if user-defined added mass curves were given.</p>
<h3>User-defined in-line added mass for combined cross-flow and in-line VIV</h3>
<p>If user-defined in-line added mass was specified, the cross-flow added mass was used if it also was specified by user-defined curves. If default cross-flow added mass curves were specified, incorrect accessing could give program termination or possibly incorrect results.</p>
<p>For IRSTYP=3; combined cross-flow and in-line VIV; the in-line added mass is used in the initial eigenvalue analysis for the in-line response frequencies. These frequencies are used as the starting values if in-line frequency iterations are performed. If not, the calculated initial mode shapes are used to establish initial response estimates for the response iterations.</p>
<h3>Avoid sporadic, false error exits after writing MatrixPlot results</h3>
<p>An uninitialized error flag could cause sporadic, false error exits after writing to or closing the _vivana.mpf fie.</p>
<h1>VIVANA 4.12.0</h1>
<h2>VIVANA 4.12.0 New / improved functionality</h2>
<h3>Print of tension and curvature time series</h3>
<p>The input parameter TSIOPPR for print of tension and curvature time series has been reactivated for concurrent response frequencies; IOPTSH = 0.</p>
<h3>Element stress concentration factors can be given</h3>
<p>The stress and fatigue damage can be estimated using element dependent stress concentration factors. Note that the stress is calculated using default stress concentration factors for the other elements.</p>
<h3>Avoid IL-frequency iteration for combined cross-flow and in-line VIV</h3>
<p>The in-line frequency iteration for combined cross-flow and in-line VIV can now optionally be avoided. This is done by defining the constant added mass by a single value.</p>
<p>If IRSTYP=3 (Combined cross-flow and in-line VIV) and constant added mass curve with NAMPT=1 is used for all sections, no IL frequency iteration is performed. The IL frequency is set to twice the CF frequency and the in-line added mass is not adjusted.</p>
<h3>Calculation of fatigue contributions</h3>
<p>The relative duration; i.e. the probability; of the current condition; may now be specified in the VIVRESPONSE FATIGUE DAMAGE data group. If a non-zero relative duration is given, the fatigue damage contributions will be found as the calculated fatigue damage scaled by the relative duration. The fatigue contributions will be written to the _vivana.mpf file in addition to the calculated fatigue damage.</p>
<h2>VIVANA 4.12.0 Corrected errors</h2>
<h3>VIV analysis with flex-joint</h3>
<p>Corrected a long-standing error in stiffness contributions from flex-joints. The error could cause incorrect response for systems with flex-joints.</p>
<p>Also corrected in VIVANA 4.10.5.</p>
<h3>Corrected some default values</h3>
<p>Some input parameters were not set to their default value if input was not given by the user. This has been corrected.</p>
<h3>Corrected the line length used in result presentation</h3>
<p>The accumulated line length used in result presentation is now calculated from the actual stress-free segment lengths given in the line type definition in INPMOD; i.e. parameter SLGTH0 if it is given, otherwise SLGTH.</p>
<p>The line length is used for results on the _vivana.mpf file and for fatigue damage on the _vivana.res file. Previously, the line length in VIVANA was calculated from the final static nodal coordinates.</p>
<p>Significant changes are expected for cases in which all elements do not follow each other sequentially.</p>
<p>The change in line length will be small for cases without</p>
<ul>
<li>segment length change; initially pre-stressed segments in STAMOD or segment length variation in DYNMOD</li>
<li>length changes due to temperature or pressure changes</li>
<li>element length modification for elements on / leaving a winch</li>
<li>large static elongation / compression (VIVANA and OUTMOD)</li>
</ul>
<h3>Correct calculation of 1D modes for complicated systems</h3>
<p>A longstanding error in the calculation of mode shapes in the VIV active plane has been corrected. The error occurred for systems where the elements were not all in a single row one after the other. The error could cause incorrect ranking of response frequencies or program termination.</p>
<p>No consequence for simple systems where all elements are in a row one after the other.</p>
<p>Error since <code>VIVANA</code> 4.0. Also corrected in <code>VIVANA</code> 4.10.2.</p>
<h3>Correction for SN curves given with five straight lines</h3>
<p>Corrected storage of input SN curves defined with five straight lines. No consequence is all SN curves were defined with fewer than five straight lines.</p>
<p>Also corrected in <code>VIVANA</code> 4.10.2.</p>
<h3>VIVANA Theory Manual</h3>
<p>Fixed the format of a figure in the pdf version of the VIVANA Theory Manual that caused errors when printing or paging through the chapter "Calculation of Response Frequencies".</p>
<p>Also corrected in <code>VIVANA</code> 4.10.1.</p>
<h2>VIVANA 4.12.0 Known issues</h2>
<p>No known issues in the 4.12.0 version.</p>
<h2>VIVANA 4.12.0 Input changes</h2>
<p>Input files used in version 4.10 can be used unchanged.</p>
<h2>VIVANA 4.12.0 Removed functionality</h2>
<p>No previously available functionality have been removed in version 4.12.0.</p>
<h2>VIVANA 4.12.0 Deprecated functionality</h2>
<p>No functionality is deprecated in the 4.12.0 version.</p>
<h1>VIVANA 4.10.0</h1>
<p>Initial release of <code>VIVANA</code> 4.10.x.</p>
<h2>VIVANA 4.10.0 Input changes</h2>
<p>Input files used in version 4.8 can be used unchanged.</p>
<p>Input for new functionality is described in the User Manual.</p>
<h2>VIVANA 4.10.0 Corrected errors</h2>
<p>No error corrections to VIVANA 4.10.0</p>
<h2>VIVANA 4.10.0 New / improved functionality</h2>
<h3>User-defined in-line coefficients</h3>
<p>User-defined excitation, added mass and excitation zone coefficients may now be given for pure in-line loading, <code>IRSTYP</code> = 2.</p>
<h3>User-defined excitation coefficients in table format</h3>
<p>User-defined excitation curves in table format may now be given for combined cross-flow and in-line loading, <code>IRSTYP</code> = 3.</p>
<h3>Results on _vivana.mpf file</h3>
<p>The initial response estimate is written to the _vivana.mpf file for all response frequencies.</p>
<p>Final results are written even if the response is below the limit.</p>
<p>Avoid duplication of matrices when response iterations have not converged and the last iteration is identified as the best.</p>
<p>For combined cross-flow and in-line VIV loads (<code>IRSTYP</code> = 3) and <code>IPRINT</code> = 5, write both CF and IL response for all iterations.</p>
<p>For <code>IOPTSH = 1</code>; consecutive response frequencies or time-sharing; the relative duration of each response frequency is now reported on the _vivana.mpf file.</p>
<h3>Reporting of response calculation convergence</h3>
<p>A warning is printed on the _vivana.res file if any of the response calculations did not converge. Detailed information about the response convergence is then also written on the _vivana.res file.</p>
<p>Detailed information about the response convergence is written on the _vivana.mpf file.</p>
<p>The matrix All response iterations converged? with three values is also written on the _vivana.mpf file. The first two numbers are 1 if all response calculations have converged and 0 if any did not converge. The third is 1 if all the response calculations with significant response converged, 0 if any of these did not. The key for the two "Y" values give the number of response calculations that converged.</p>
<h2>VIVANA 4.10.0 Removed functionality</h2>
<p>No previously available functionality have been removed in version 4.10.0.</p>
<h2>VIVANA 4.10.0 Deprecated functionality</h2>
<p>No functionality is deprecated in the 4.10.0 version.</p>
<h1>VINANA 4.8</h1>
<h2>VIVANA 4.8 Input changes</h2>
<p>Input files used in version 4.6 can be used unchanged in version 4.8.</p>
<h2>VIVANA 4.8 Corrected errors</h2>
<h3>Error in seafloor damping in VIVANA</h3>
<p>Seafloor damping may be specified for analyses using the 3D seafloor formulation; i.e. <code>IBOR3D = 1</code> or <code>IBTANG = -1</code>. A longstanding error has caused this damping to be incorrectly applied in <code>VIVANA</code> since 3.6. No error if the damping was less than the damping specified in <code>VIVANA</code>. The error has been corrected.</p>
<p>Corrected in <code>VIVANA</code> 4.8.7</p>
<h3>Linux binary files</h3>
<p>The record length of the binary files was set to four times the correct value. The .ffi, .sam, .raf, and .bin files were therefore four time their necessary size. The .bin files from <code>STAMOD</code> were not comparable with their documentation and pre-existing tools for reading them.</p>
<p>Error since 4.8.0. Corrected in <code>VIVANA</code> 4.8.3</p>
<h2>VIVANA 4.8 New / improved functionality</h2>
<h3>New Linux release</h3>
<p>The new Linux release of <code>SIMO</code>, <code>RIFLEX</code> and <code>VIVANA</code> is 64-bit and solves several issues. Unfortunately, this means that 32-bit Linux operating systems are no longer supported.</p>
<ul>
<li>Supports more than the 32-bit imposed limit of 2 GB of RAM</li>
<li>No need to install 32-bit support libraries separately</li>
<li>No special considerations are needed for writing output files larger than 2 GB</li>
<li>The necessary runtime libraries are included in the installation package and no special consideration is needed for installation; the package is now fully relocatable</li>
</ul>
<p>The package has been tested on the following Linux distributions:</p>
<ul>
<li>CentOS 7</li>
<li>Ubuntu 14.04 LTS</li>
<li>Linux Mint 17</li>
</ul>
<h2>VIVANA 4.8 Removed functionality</h2>
<p>No previously available functionality have been removed in the 4.8 release.</p>
<h2>VIVANA 4.8 Deprecated functionality</h2>
<p>No functionality is deprecated in the 4.8 version.</p>
<h1>VIVANA 4.6</h1>
<h2>VIVANA 4.6 Input changes</h2>
<p>4.2 and 4.4 input files may be used unchanged.</p>
<h2>VIVANA 4.6 Removed functionality</h2>
<p>No <code>VIVANA</code> 4.4 functionality has been removed in <code>VIVANA</code> 4.6.</p>
<h2>VIVANA 4.6 Deprecated functionality</h2>
<p>No <code>VIVANA</code> 4.4 functionality is currently deprecated.</p>
<h1>VIVANA 4.4</h1>
<h2>VIVANA 4.4 Input changes</h2>
<p>4.2 input files may be used unchanged.</p>
<h2>VIVANA 4.4 Corrected errors</h2>
<h3>Specification of hydrodynamic coefficients</h3>
<p>Hydrodynamic properties are specified in the data group SECTION PROPERTY SPECIFICATION. <code>VIVANA</code> will now check that coefficients are specified for all segments in the model. This was not previously checked and could give errors.</p>
<h3>Corrected radius of gyration for CRS0 cross section</h3>
<p>The radius of gyration for CRS0 cross sections has been corrected in <code>RIFLEX</code>. This concerns both CRS0 cross sections explicitly specified in the model as well as CRS0 cross sections generated for a stress joint specification. Please see the <code>RIFLEX</code> 4.4.1 Release Notes for details.</p>
<p>For most cases, the correction is not expected to cause significant changes in the response. For some cases, however, the correction may lead to changes in convergence and estimated response. Note that changes in estimated stress are exponentially increased by the slope of the SN-curve to changes in estimated fatigue damage. With a slope of 4.0 in the SN curve, a 2 % increase in stress will give an 8 % increase in estimated fatigue damage.</p>
<p>Corrected in <code>VIVANA</code> 4.4.1.</p>
<h3>Non-unique matrix titles</h3>
<p>If more than 20 response frequencies contribute to the response, the plots of response amplitude, curvature, axial force, bending moment and stress are split into several matrices on the <code>_vivana.mpf</code> file. These matrices will now have unique names. Truncation of the legends is now avoided, so all frequencies will be plotted.</p>
<p>These corrections aid examining and extracting intermediate results. No change to final results; e.g. fatigue damage.</p>
<p>Non&ndash;unique matrix names may still occur if the response iterations do not converge and the last iteration is identified as giving the best response estimate.</p>
<p>Corrected in <code>VIVANA</code> 4.4.2.</p>
<h3>Correct formatting of .mpf files</h3>
<p>Formatting of units in .mpf files are now consistent with <code>RIFLEX</code>.</p>
<h3>Minor improvements</h3>
<p>Blank space is added around some numbers printed on the .res files. This has been done to increase readability and to facilitate comparison of numerical results.</p>
<p>Minor improvements in error handling and layout.</p>
<h2>VIVANA 4.4 Miscellaneous</h2>
<h3>Run time environment</h3>
<p>Windows versions 4.4 and higher are 64 bit executables and therefore require different Fortran and Java DLLs than earlier version. The necessary DLLs are included in the download package. The preformance is improved.</p>
<h1>VIVANA 4.2</h1>
<h2>VIVANA 4.2 Input changes</h2>
<h3>INPMOD and STAMOD input change</h3>
<p><code>INPMOD</code> and <code>STAMOD</code> 4.0 input files may be used unchanged.</p>
<p>Input for new functionality is described in the <code>RIFLEX</code> User Manual.</p>
<h3>Input file version identifier</h3>
<p>The input file version <code>CHVERS</code> must now be given in the data group VIVANA CONTROL INFORMATION at the beginning of the input file:</p>
<div class="fragment"><div class="line">VIVANA CONTROL INFORMATION 4.0</div>
</div><!-- fragment --><p> At present <code>CHVERS</code> must be 4.0.0 or higher.</p>
<h3>Input to response analysis reorganized</h3>
<p>The input parameters <code>SCAINI</code>, <code>REXPAL</code> and <code>REXPAH</code> have been added to the data group RESPONSE ANALYSIS PARAMETERS: </p>
<div class="fragment"><div class="line">RESPONSE ANALYSIS PARAMETERS</div>
<div class="line"><span class="stringliteral">&#39; reldam iopfrc iprint</span></div>
<div class="line"><span class="stringliteral">0.010 1 1</span></div>
<div class="line"><span class="stringliteral">&#39;</span> ifrit max_niter ilim conlim scaini</div>
<div class="line">2 40 AMPNOR 0.0005 0.5</div>
<div class="line"><span class="stringliteral">&#39; ioptsh nuddis adlim rexpal rexpah</span></div>
<div class="line"><span class="stringliteral">1 0 / 0.2 1.0</span></div>
</div><!-- fragment --><p><code>SCAINI</code> specifies the scaling of the initial response estimate. The default value is 0.5, giving the same initial response estimate as in <code>VIVANA</code> 4.0.</p>
<p><code>REXPAL</code> and <code>REXPAH</code> are used to limit the number of response frequencies. The default values are 0.0, i.e. no cut-off applied.</p>
<h3>Input to fatigue analysis reorganized</h3>
<p>A new option for the fatigue analysis IOPDAT has been added to the data group VIVRESPONSE FATIGUE DAMAGE. For <code>IOPDAT</code> = 3 the fatigue damage is calculated directly from the harmonic stress amplitudes. Valid for single-frequency response only.</p>
<div class="fragment"><div class="line">VIVRESPONSE FATIGUE DAMAGE</div>
<div class="line"><span class="stringliteral">&#39; iopfat nsect npcs ioppr tsioppr chtsprn</span></div>
<div class="line"><span class="stringliteral">3 0 4 0</span></div>
<div class="line"><span class="stringliteral">&#39;</span> dscfa dscfy dscfz asi wsti thi rfact</div>
<div class="line">1.0 1.0 1.0 0.030449981 0.003549035 / 0.001</div>
</div><!-- fragment --><h2>VIVANA 4.2 New functionality</h2>
<h3>Option to limit the number of concurrent response frequencies</h3>
<p>The new input parameters <code>REXPAL</code> and <code>REXPAH</code> allow the user to limit the number of response frequencies. Response frequencies with excitation parameter below the user-specified cut-off values are omitted. The cut-off values are given as fractions of the highest excitation parameter value, which is for the dominating frequency. Separate cut-off values are given for response frequencies below and above the dominating frequency.</p>
<p>At present, the default values are zero so no response frequencies will be omitted. Specifying <code>REXPAL</code> = 0.2 and <code>REXPAH</code> = 1.0 will omit all response frequencies above the dominating frequency and those below that have excitation parameters of less than 20 % of the peak value. This agrees well with experiments with linearly sheared current and a constant diameter.</p>
<h3>User input for scaling the initial response estimate</h3>
<p>The user may give a scaling factor for the initial response estimate or, alternatively, the scaling may be based on the excitation curves in the excitation zone. The input is added to aid in analyses with convergence problems. For some cases, the scaling based on the excitation curves gives improved convergence. The default is to scale so that the maximum amplitude is 0.5 average diameters, corresponding to the built-in values in previous versions.</p>
<h3>Direct calculation of fatigue from constant stress amplitudes</h3>
<p>Add option <code>IOPFAT</code> = 3 for direct calculation of fatigue assuming constant stress amplitudes. This option may be used for single-frequency response only. Currently available for <code>IRSTYP</code> = 1 or 2; i.e. pure CF loading; or pure IL loading; and a single response frequency.</p>
<h3>No VIV response found</h3>
<p>The case of no VIV response is no longer reported as an error. Note that the <code>_vivana.mpf</code> file will in this case be empty,</p>
<h3>Modelling and static analysis (INPMOD and STAMOD)</h3>
<p>Please refer to the <code>RIFLEX</code> 4.2 Release Notes.</p>
<h2>VIVANA 4.2 Removed functionality</h2>
<p>No <code>VIVANA</code> 4.0 functionality has been removed in <code>VIVANA</code> 4.2.</p>
<h2>VIVANA 4.2 Deprecated functionality</h2>
<p>No <code>VIVANA</code> 4.0 functionality has been deprecated in <code>VIVANA</code> 4.2.</p>
<h2>VIVANA 4.2 Miscellaneous</h2>
<h3>Java and HLALIB.jar</h3>
<p>The included Java folder and the <code>HLALIB.jar</code> file have been updated in the Windows installation <code>.zip</code> file. </p>
</div></div><!-- contents -->
	</body>
</html>