' #  Inputfile for test of VIVANA                              #
' #                                                            #
' #  Test case :  Vertical riser with buoyancy                 #
' #               in uniform or sheared current                #
' #               marine growth NORSOK N-003                   #
' #                                                            #
' #  Module    : RIFLEX STAMOD                                 #
' #                                                            #
' #  VIVANA input file  : drill_growth_vivana.inp              #
' #                                                            #
' #  RIFLEX input files : drill_growth_inpmod.inp              #
' #                       drill_growth_stamod.inp              #
' #  Date        : 27/3 - 2017    grob                         #
' **************************************************************
'
' ----------------------------------------------------------------
        STAMOD CONTROL INFORMATION 3.8
' ----------------------------------------------------------------
   - VIVANA Test case.
   - Vertical riser in constant or sheared current.
   - 600 m waterdepth, marine growth 
' ----------------------------------------------------------------
'
'       irunco   idris    ianal iprdat iprcat  iprfem  ipform iprnor
        1        VERTIC   2     5      1        5       1      1
'
' ----------------------------------------------------------------
        RUN IDENTIFICATION
' ----------------------------------------------------------------
'       idsta
        STVERT
'
' ----------------------------------------------------------------
'
        ENVIRONMENT REFERENCE IDENTIFIER
'       idenv
        ENV1
'
' ----------------------------------------------------------------
'            STATIC ANALYSIS WITH FIXED PARAMETERS
' ----------------------------------------------------------------
        STATIC CONDITION INPUT
' nlcomp  icurin  curfac  iwindin
  1       4       1.0     0     
'
'-------------------------------------------------------
'   Top tension: Riser end is at node 26 of segment 3  
' ------------------------------------------------------
'
'       ilin      ilseg    ilnode     ildof  rlmag
        1         3        26         3      800.
' lcons   isolvr
  1       1
'
'
'-------------------------------------------------------
        COMPUTATIONAL PROCEDURE
'
' ------------------------------------------------------
'       ameth
        FEM
'
        FEM ANALYSIS PARAMETERS DEFINE LOADING SEQUENCE
'
'-------------------------------------------------------
'
   LOAD GROUP DATA
'      nstep    maxit   racu
          5      30     1.E-7
'      LOTYPE
       DISP 
       TENS
' ------
   LOAD GROUP DATA
'      nstep   maxit    racu
         4      100     1.E-7
'      LOTYPE
       VOLU
       SFOR
' ------
   LOAD GROUP DATA
'      nstep   maxit    racu
         4      50     1.1e-5
'      lotype  NLSPEC
       GROWTH   1
'
'      MGFAC
       1.0
' -------
   LOAD GROUP DATA
'      nstep   maxit    racu
         10      50     1.E-7
'      LOTYPE
       CURR  
'
' ------------------------------------------------------
'   Definition of offset by use of parameter variation option 
'
    PARAMETER VARIATION DEFINITION
'
'   nstvar   iofpos   icurvar   ifovar   maxipv racupv
    1        1        0         0        15     1.E-5
'
    STATIC OFFSET INCREMENTS
'
'   iref   dxoff   dyoff    dzoff   irot   drot
    2      12      0        0       0      
'
'   Mandatory data when parameter variation:
    STAMOD PRINT CONTROL
'
'   istep  isfor  ispos
    1      1      1
'-------------------------------------------------------
    END