 PRINT OF                : WIND FATIGUE DIAGOSTICS

 RUN NAME                : X505B   
 RUN DESCRIPTION         : None                                                                    
 RESULTS INTERFACE FILE  : X505BR1.SIN                                                                     
 PROGRAM/ID/RELEASE DATE : FRAMEWORK   D4.0-00     08-MAY-2020  08:08:10

 ************************************************************************

 SCF factors: S1  S2  S3  S4  S5  S6  S7  S8
 -------------------------------------------
 S1 = Axial                 Crown  Chord side
 S2 = Axial                 Crown  Brace side
 S3 = In-plane Bending      Crown  Chord side
 S4 = In-plane Bending      Crown  Brace side
 S5 = Axial                 Saddle Chord side
 S6 = Axial                 Saddle Brace side
 S7 = Out-of-plane Bending  Saddle Chord side
 S8 = Out-of-plane Bending  Saddle Brace side


  NO OF MODES                             2
  RANGING FROM PLANE                      1
            TO PLANE                      4
  JOINT NUMBER IS                       101
  OTHER END NODE IS                       0
  RANGE NODE IS                         303
Jnt 201     Pln 1: 2 chord elements and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 201     202     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  8.09  4.18  3.31  2.85 11.55  9.05  8.32  6.27
Jnt 201     Pln 3: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   BrcEnds 201     206     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  6.68  5.47  3.31  2.85  6.68  5.47  8.60  6.47
                   BrcEnds 201     303     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  3.63  2.58  2.16  3.30  3.63  2.58  5.55  4.18
Jnt 201     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   BrcEnds 201     202     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
                   BrcEnds 201     206     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
Jnt 202     Pln 1: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  1.236E-01 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 202     101     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.82  7.00  2.64  2.38  2.92  2.58  4.53  2.45
                   BrcEnds 202     102     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.82  7.00  2.64  2.38  2.92  2.58  4.53  2.45
Jnt 202     Pln 4: 2 elements meet at the joint within the analysis plane. Connection classified as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 202     201     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 202     203     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 203     Pln 1: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   BrcEnds 203     202     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  6.92  5.63  3.31  2.85  6.92  5.63  8.50  6.40
                   BrcEnds 203     301     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  3.69  2.59  2.13  3.32  3.69  2.59  5.35  4.03
Jnt 203     Pln 2: 2 chord elements and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 203     204     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  8.11  4.18  3.31  2.85 11.56  9.10  8.36  6.29
Jnt 203     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   BrcEnds 203     202     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
                   BrcEnds 203     204     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
Jnt 204     Pln 2: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  1.239E-01 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 204     102     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.99  7.00  2.67  2.36  3.00  2.63  4.65  2.51
                   BrcEnds 204     103     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.66  7.00  2.61  2.39  2.84  2.53  4.41  2.38
Jnt 204     Pln 4: 2 elements meet at the joint within the analysis plane. Connection classified as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 204     203     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 204     205     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 205     Pln 2: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   BrcEnds 205     204     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  7.12  5.74  3.30  2.85  7.12  5.74  8.38  6.31
                   BrcEnds 205     302     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  3.71  2.57  2.09  3.34  3.71  2.57  5.12  3.86
Jnt 205     Pln 3: 2 chord elements and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 205     206     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  8.08  4.18  3.30  2.85 11.53  8.98  8.26  6.22
Jnt 205     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   BrcEnds 205     204     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
                   BrcEnds 205     206     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
Jnt 206     Pln 3: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  1.239E-01 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 206     103     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.66  7.00  2.61  2.39  2.84  2.53  4.41  2.38
                   BrcEnds 206     101     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.99  7.00  2.67  2.36  3.00  2.63  4.65  2.51
Jnt 206     Pln 4: 2 elements meet at the joint within the analysis plane. Connection classified as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 206     205     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 206     201     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 301     Pln 1: 1 chord element  and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  9.206E-03 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 301     203     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.28  2.16  2.49  3.14  3.89  2.27  3.77  2.84
                   BrcEnds 301     302     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.31  2.85  7.68  4.98  7.22  5.44
Jnt 301     Pln 3: 1 chord element  and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 301     303     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.31  2.85  7.72  5.01  7.25  5.46
Jnt 301     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 301     302     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 301     303     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 302     Pln 1: 1 chord element  and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 302     301     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.31  2.85  7.68  4.98  7.22  5.44
Jnt 302     Pln 2: 1 chord element  and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  1.248E-02 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 302     205     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.29  2.16  2.46  3.15  3.77  2.20  3.66  2.76
                   BrcEnds 302     303     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.31  2.85  7.72  5.01  7.25  5.46
Jnt 302     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 302     301     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 302     303     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 303     Pln 2: 1 chord element  and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 303     302     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.30  2.85  7.63  4.93  7.17  5.40
Jnt 303     Pln 3: 1 chord element  and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  4.867E-03 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 303     201     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.28  2.16  2.51  3.13  3.98  2.32  3.86  2.91
                   BrcEnds 303     301     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.30  2.85  7.63  4.93  7.17  5.40
Jnt 303     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 303     302     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 303     301     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60




 ************************************************************************

 PRINT OF                : WIND FATIGUE DIAGOSTICS

 RUN NAME                : X505B   
 RUN DESCRIPTION         : None                                                                    
 RESULTS INTERFACE FILE  : X505BR1.SIN                                                                     
 PROGRAM/ID/RELEASE DATE : FRAMEWORK   D4.0-00     08-MAY-2020  08:08:10

 ************************************************************************

 SCF factors: S1  S2  S3  S4  S5  S6  S7  S8
 -------------------------------------------
 S1 = Axial                 Crown  Chord side
 S2 = Axial                 Crown  Brace side
 S3 = In-plane Bending      Crown  Chord side
 S4 = In-plane Bending      Crown  Brace side
 S5 = Axial                 Saddle Chord side
 S6 = Axial                 Saddle Brace side
 S7 = Out-of-plane Bending  Saddle Chord side
 S8 = Out-of-plane Bending  Saddle Brace side


  NO OF MODES                             2
  RANGING FROM PLANE                      1
            TO PLANE                      4
  JOINT NUMBER IS                       101
  OTHER END NODE IS                       0
  RANGE NODE IS                         303
Jnt 201     Pln 1: 2 chord elements and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 201     202     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  8.09  4.18  3.31  2.85 11.55  9.05  8.32  6.27
Jnt 201     Pln 3: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   BrcEnds 201     206     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  6.68  5.47  3.31  2.85  6.68  5.47  8.60  6.47
                   BrcEnds 201     303     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  3.63  2.58  2.16  3.30  3.63  2.58  5.55  4.18
Jnt 201     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   BrcEnds 201     202     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
                   BrcEnds 201     206     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
Jnt 202     Pln 1: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  1.236E-01 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 202     101     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.82  7.00  2.64  2.38  2.92  2.58  4.53  2.45
                   BrcEnds 202     102     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.82  7.00  2.64  2.38  2.92  2.58  4.53  2.45
Jnt 202     Pln 4: 2 elements meet at the joint within the analysis plane. Connection classified as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 202     201     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 202     203     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 203     Pln 1: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   BrcEnds 203     202     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  6.92  5.63  3.31  2.85  6.92  5.63  8.50  6.40
                   BrcEnds 203     301     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  3.69  2.59  2.13  3.32  3.69  2.59  5.35  4.03
Jnt 203     Pln 2: 2 chord elements and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 203     204     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  8.11  4.18  3.31  2.85 11.56  9.10  8.36  6.29
Jnt 203     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   BrcEnds 203     202     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
                   BrcEnds 203     204     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
Jnt 204     Pln 2: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  1.239E-01 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 204     102     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.99  7.00  2.67  2.36  3.00  2.63  4.65  2.51
                   BrcEnds 204     103     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.66  7.00  2.61  2.39  2.84  2.53  4.41  2.38
Jnt 204     Pln 4: 2 elements meet at the joint within the analysis plane. Connection classified as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 204     203     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 204     205     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 205     Pln 2: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   BrcEnds 205     204     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  7.12  5.74  3.30  2.85  7.12  5.74  8.38  6.31
                   BrcEnds 205     302     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  3.71  2.57  2.09  3.34  3.71  2.57  5.12  3.86
Jnt 205     Pln 3: 2 chord elements and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 205     206     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  8.08  4.18  3.30  2.85 11.53  8.98  8.26  6.22
Jnt 205     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   BrcEnds 205     204     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
                   BrcEnds 205     206     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
Jnt 206     Pln 3: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  1.239E-01 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 206     103     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.66  7.00  2.61  2.39  2.84  2.53  4.41  2.38
                   BrcEnds 206     101     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.99  7.00  2.67  2.36  3.00  2.63  4.65  2.51
Jnt 206     Pln 4: 2 elements meet at the joint within the analysis plane. Connection classified as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 206     205     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 206     201     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 301     Pln 1: 1 chord element  and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  9.206E-03 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 301     203     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.28  2.16  2.49  3.14  3.89  2.27  3.77  2.84
                   BrcEnds 301     302     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.31  2.85  7.68  4.98  7.22  5.44
Jnt 301     Pln 3: 1 chord element  and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 301     303     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.31  2.85  7.72  5.01  7.25  5.46
Jnt 301     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 301     302     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 301     303     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 302     Pln 1: 1 chord element  and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 302     301     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.31  2.85  7.68  4.98  7.22  5.44
Jnt 302     Pln 2: 1 chord element  and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  1.248E-02 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 302     205     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.29  2.16  2.46  3.15  3.77  2.20  3.66  2.76
                   BrcEnds 302     303     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.31  2.85  7.72  5.01  7.25  5.46
Jnt 302     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 302     301     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 302     303     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 303     Pln 2: 1 chord element  and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 303     302     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.30  2.85  7.63  4.93  7.17  5.40
Jnt 303     Pln 3: 1 chord element  and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  4.867E-03 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 303     201     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.28  2.16  2.51  3.13  3.98  2.32  3.86  2.91
                   BrcEnds 303     301     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.30  2.85  7.63  4.93  7.17  5.40
Jnt 303     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 303     302     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 303     301     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60




 ************************************************************************

 PRINT OF                : WIND FATIGUE DIAGOSTICS

 RUN NAME                : X505B   
 RUN DESCRIPTION         : None                                                                    
 RESULTS INTERFACE FILE  : X505BR1.SIN                                                                     
 PROGRAM/ID/RELEASE DATE : FRAMEWORK   D4.0-00     08-MAY-2020  08:08:11

 ************************************************************************

 SCF factors: S1  S2  S3  S4  S5  S6  S7  S8
 -------------------------------------------
 S1 = Axial                 Crown  Chord side
 S2 = Axial                 Crown  Brace side
 S3 = In-plane Bending      Crown  Chord side
 S4 = In-plane Bending      Crown  Brace side
 S5 = Axial                 Saddle Chord side
 S6 = Axial                 Saddle Brace side
 S7 = Out-of-plane Bending  Saddle Chord side
 S8 = Out-of-plane Bending  Saddle Brace side


  NO OF MODES                             2
  RANGING FROM PLANE                      1
            TO PLANE                      4
  JOINT NUMBER IS                       101
  OTHER END NODE IS                       0
  RANGE NODE IS                         303
Jnt 201     Pln 1: 2 chord elements and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 201     202     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  8.09  4.18  3.31  2.85 11.55  9.05  8.32  6.27
Jnt 201     Pln 3: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   BrcEnds 201     206     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  6.68  5.47  3.31  2.85  6.68  5.47  8.60  6.47
                   BrcEnds 201     303     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  3.63  2.58  2.16  3.30  3.63  2.58  5.55  4.18
Jnt 201     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   BrcEnds 201     202     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
                   BrcEnds 201     206     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
Jnt 202     Pln 1: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  1.236E-01 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 202     101     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.82  7.00  2.64  2.38  2.92  2.58  4.53  2.45
                   BrcEnds 202     102     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.82  7.00  2.64  2.38  2.92  2.58  4.53  2.45
Jnt 202     Pln 4: 2 elements meet at the joint within the analysis plane. Connection classified as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 202     201     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 202     203     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 203     Pln 1: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   BrcEnds 203     202     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  6.92  5.63  3.31  2.85  6.92  5.63  8.50  6.40
                   BrcEnds 203     301     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  3.69  2.59  2.13  3.32  3.69  2.59  5.35  4.03
Jnt 203     Pln 2: 2 chord elements and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 203     204     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  8.11  4.18  3.31  2.85 11.56  9.10  8.36  6.29
Jnt 203     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   BrcEnds 203     202     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
                   BrcEnds 203     204     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
Jnt 204     Pln 2: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  1.239E-01 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 204     102     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.99  7.00  2.67  2.36  3.00  2.63  4.65  2.51
                   BrcEnds 204     103     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.66  7.00  2.61  2.39  2.84  2.53  4.41  2.38
Jnt 204     Pln 4: 2 elements meet at the joint within the analysis plane. Connection classified as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 204     203     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 204     205     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 205     Pln 2: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   BrcEnds 205     204     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  7.12  5.74  3.30  2.85  7.12  5.74  8.38  6.31
                   BrcEnds 205     302     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  3.71  2.57  2.09  3.34  3.71  2.57  5.12  3.86
Jnt 205     Pln 3: 2 chord elements and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 205     206     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  8.08  4.18  3.30  2.85 11.53  8.98  8.26  6.22
Jnt 205     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   BrcEnds 205     204     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
                   BrcEnds 205     206     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
Jnt 206     Pln 3: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  1.239E-01 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 206     103     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.66  7.00  2.61  2.39  2.84  2.53  4.41  2.38
                   BrcEnds 206     101     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.99  7.00  2.67  2.36  3.00  2.63  4.65  2.51
Jnt 206     Pln 4: 2 elements meet at the joint within the analysis plane. Connection classified as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 206     205     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 206     201     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 301     Pln 1: 1 chord element  and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  9.206E-03 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 301     203     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.28  2.16  2.49  3.14  3.89  2.27  3.77  2.84
                   BrcEnds 301     302     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.31  2.85  7.68  4.98  7.22  5.44
Jnt 301     Pln 3: 1 chord element  and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 301     303     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.31  2.85  7.72  5.01  7.25  5.46
Jnt 301     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 301     302     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 301     303     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 302     Pln 1: 1 chord element  and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 302     301     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.31  2.85  7.68  4.98  7.22  5.44
Jnt 302     Pln 2: 1 chord element  and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  1.248E-02 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 302     205     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.29  2.16  2.46  3.15  3.77  2.20  3.66  2.76
                   BrcEnds 302     303     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.31  2.85  7.72  5.01  7.25  5.46
Jnt 302     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 302     301     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 302     303     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 303     Pln 2: 1 chord element  and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 303     302     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.30  2.85  7.63  4.93  7.17  5.40
Jnt 303     Pln 3: 1 chord element  and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  4.867E-03 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 303     201     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.28  2.16  2.51  3.13  3.98  2.32  3.86  2.91
                   BrcEnds 303     301     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.30  2.85  7.63  4.93  7.17  5.40
Jnt 303     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 303     302     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 303     301     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60




 ************************************************************************

 PRINT OF                : WIND FATIGUE DIAGOSTICS

 RUN NAME                : X505B   
 RUN DESCRIPTION         : None                                                                    
 RESULTS INTERFACE FILE  : X505BR1.SIN                                                                     
 PROGRAM/ID/RELEASE DATE : FRAMEWORK   D4.0-00     08-MAY-2020  08:08:11

 ************************************************************************

 SCF factors: S1  S2  S3  S4  S5  S6  S7  S8
 -------------------------------------------
 S1 = Axial                 Crown  Chord side
 S2 = Axial                 Crown  Brace side
 S3 = In-plane Bending      Crown  Chord side
 S4 = In-plane Bending      Crown  Brace side
 S5 = Axial                 Saddle Chord side
 S6 = Axial                 Saddle Brace side
 S7 = Out-of-plane Bending  Saddle Chord side
 S8 = Out-of-plane Bending  Saddle Brace side


  NO OF MODES                             2
  RANGING FROM PLANE                      1
            TO PLANE                      4
  JOINT NUMBER IS                       101
  OTHER END NODE IS                       0
  RANGE NODE IS                         303
Jnt 201     Pln 1: 2 chord elements and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 201     202     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  8.09  4.18  3.31  2.85 11.55  9.05  8.32  6.27
Jnt 201     Pln 3: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   BrcEnds 201     206     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  6.68  5.47  3.31  2.85  6.68  5.47  8.60  6.47
                   BrcEnds 201     303     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  3.63  2.58  2.16  3.30  3.63  2.58  5.55  4.18
Jnt 201     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   BrcEnds 201     202     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
                   BrcEnds 201     206     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
Jnt 202     Pln 1: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  1.236E-01 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 202     101     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.82  7.00  2.64  2.38  2.92  2.58  4.53  2.45
                   BrcEnds 202     102     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.82  7.00  2.64  2.38  2.92  2.58  4.53  2.45
Jnt 202     Pln 4: 2 elements meet at the joint within the analysis plane. Connection classified as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 202     201     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 202     203     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 203     Pln 1: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   BrcEnds 203     202     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  6.92  5.63  3.31  2.85  6.92  5.63  8.50  6.40
                   BrcEnds 203     301     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  3.69  2.59  2.13  3.32  3.69  2.59  5.35  4.03
Jnt 203     Pln 2: 2 chord elements and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 203     204     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  8.11  4.18  3.31  2.85 11.56  9.10  8.36  6.29
Jnt 203     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   BrcEnds 203     202     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
                   BrcEnds 203     204     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
Jnt 204     Pln 2: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  1.239E-01 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 204     102     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.99  7.00  2.67  2.36  3.00  2.63  4.65  2.51
                   BrcEnds 204     103     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.66  7.00  2.61  2.39  2.84  2.53  4.41  2.38
Jnt 204     Pln 4: 2 elements meet at the joint within the analysis plane. Connection classified as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 204     203     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 204     205     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 205     Pln 2: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   BrcEnds 205     204     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  7.12  5.74  3.30  2.85  7.12  5.74  8.38  6.31
                   BrcEnds 205     302     SNcrv DOE-T            K -jnt   Scf EFTHYMIOU  3.71  2.57  2.09  3.34  3.71  2.57  5.12  3.86
Jnt 205     Pln 3: 2 chord elements and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 205     206     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  8.08  4.18  3.30  2.85 11.53  8.98  8.26  6.22
Jnt 205     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   BrcEnds 205     204     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
                   BrcEnds 205     206     SNcrv DOE-T            BentCan  Scf BENTCAN    5.00  5.00  5.00  5.00  5.00  5.00  5.00  5.00
Jnt 206     Pln 3: 2 chord elements and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  1.239E-01 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 206     103     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.66  7.00  2.61  2.39  2.84  2.53  4.41  2.38
                   BrcEnds 206     101     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU 14.99  7.00  2.67  2.36  3.00  2.63  4.65  2.51
Jnt 206     Pln 4: 2 elements meet at the joint within the analysis plane. Connection classified as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 206     205     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 206     201     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 301     Pln 1: 1 chord element  and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  9.206E-03 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 301     203     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.28  2.16  2.49  3.14  3.89  2.27  3.77  2.84
                   BrcEnds 301     302     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.31  2.85  7.68  4.98  7.22  5.44
Jnt 301     Pln 3: 1 chord element  and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 301     303     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.31  2.85  7.72  5.01  7.25  5.46
Jnt 301     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 301     302     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 301     303     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 302     Pln 1: 1 chord element  and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 302     301     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.31  2.85  7.68  4.98  7.22  5.44
Jnt 302     Pln 2: 1 chord element  and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  1.248E-02 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 302     205     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.29  2.16  2.46  3.15  3.77  2.20  3.66  2.76
                   BrcEnds 302     303     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.31  2.85  7.72  5.01  7.25  5.46
Jnt 302     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 302     301     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 302     303     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
Jnt 303     Pln 2: 1 chord element  and  1 braces meet at the joint within the analysis plane (evaluated as T joint).
                   BrcEnds 303     302     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.30  2.85  7.63  4.93  7.17  5.40
Jnt 303     Pln 3: 1 chord element  and  2 braces meet at the joint within the analysis plane (K joint tried).              
                   Overlapping K-joint. Overlap  4.867E-03 (>0.0). T -jnt   Scf used. Alt. try 'Read' Scfs option.
                   BrcEnds 303     201     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.28  2.16  2.51  3.13  3.98  2.32  3.86  2.91
                   BrcEnds 303     301     SNcrv DOE-T            T -jnt   Scf EFTHYMIOU  3.07  2.16  3.30  2.85  7.63  4.93  7.17  5.40
Jnt 303     Pln 4: 2 elements meet at the joint within the analysis plane. No chord. Connection treated as Bent Can.
                   User defined Bent Can SCFs not found.  Global Scfs are used.
                   BrcEnds 303     302     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60
                   BrcEnds 303     301     SNcrv DOE-T            BentCan  Scf BENTCAN    1.60  1.60  1.60  1.60  1.60  1.60  1.60  1.60