% BAM (BEAM ANALYSIS MODEL) - T121  Incl. Deck_Lite
% ***************************************************************
%
% This super element will be used for hydrodynamic and structural analysis
%
% **********************************
% READ IN FIRST LEVEL SUPER ELEMENTS
% **********************************
%
 READ 1
 2
 END
 ,
%
% *******************************
% BUILD UP SUPER ELEMENT ASSEMBLY
% *******************************
%
 ASSEMBLY NEW 10
 INCLUDE 
    2 
         NOPRINT-CHECK-INCLUDE
         PERFORM-INCLUDE
    2 
         MIRROR YZ-PLANE
         NOPRINT-CHECK-INCLUDE
         PERFORM-INCLUDE
    2
         MIRROR ZX-PLANE
         NOPRINT-CHECK-INCLUDE
         PERFORM-INCLUDE
    2
         ROTATE GLOBAL-AXIS Z-AXIS 180.0
         NOPRINT-CHECK-INCLUDE
         PERFORM-INCLUDE
    1 
         NOPRINT-CHECK-INCLUDE
         PERFORM-INCLUDE
 END
 ,
%
%
% ****************
% LOAD COMBINATION
% ****************
%
% Hydrodynamic load combination
%
% Must include hydrodynamic loads on all super elements
%
%                         lowglc higlc step supno indx       lowllc incr factor
 LOAD COMBINATION GROUP     1     50     1   2     1   STEP    1     4    1.0
                                             2     2   STEP    2     4    1.0
                                             2     3   STEP    3     4    1.0
                                             2     4   STEP    4     4    1.0
                                             1     1   STEP    1     1    1.0
                                             END
                  END
 END
 ..
%
%
% BOUNDARY CONDITIONS
%
% For use in structural analysis
%
% Must fix in 6 degrees of freedom since SESTRA cannot perform analysis of
% a "free-free" structure
%
 BOUNDARY FIX FIX FRE FRE FRE FRE SELECT VOLUME
          COORDINATE  27.  27. -.4 COORDINATE  28.  28. .4 END END
 BOUNDARY FRE FIX FRE FRE FRE FRE SELECT VOLUME
          COORDINATE -27.  27. -.4 COORDINATE -28.  28. .4 END END
% BOUNDARY FRE FRE FIX FRE FRE FRE SELECT VOLUME
%          COORDINATE  27. -27. -.4 COORDINATE  28. -28. .4 END END
%
OPTIMIZE 10 BANDW
..
WRITE
10
%