 PILGEN   12 PILES (INCLUDING 4 DUMMY PILES).   TEST EXAMPLE 3A, 12 JAN 1990
   
 ****************** CONTROL SECTION
 1000     CONFRC    OLD-FORCE-UNIT  = CONFRC * NEW-FORCE-UNIT  1MN  = 1000*1KN
   1.0    CONLTH    OLD-LENGTH-UNIT = CONLTH * NEW-LENGTH-UNIT  1M  = 3.28*1FT
   12     NUMPIL    NUMBER OF PILES
    2     NUMCRS    NUMBER OF CROSS SECTION TYPES
    1     NUMMAT    NUMBER OF MATERIAL TYPES
    6     NUMSEG    NUMBER OF DIFFERENT PILE SEGMENT TYPES
    0     NUMVEC    NUMBER OF LOAD VECTORS
    2     JPRINT    PRINTED OUTPUT DATA (0=NONE 1=SOME 2=FULL)
    1     JECHO     ECHO PRINT OF INPUT FILE NF11 TO FILE NF13 (0=NO 1=YES)
   
 ****************** MATERIAL TYPES SECTION
  MAT  E-MODULUS  G-MODULUS  YLD-STRENGTH  GAMMA-WALL  EPS-TEMP
   1     210E6      80E6         350E3        78        12E-6
  
 ****************** CROSS SECTION TYPE DATA
  CRS  MAT   DIAMETER   WALL   EA-NEW   EI-NEW   GA-NEW   GIP-NEW  GAMMA-FLUID
   1    1     1.067     .038     0        0        0         0        0
   2    1     1.219     .051     0        0        0         0        0
   
 ****************** PILE SEGMENT TYPE DATA
 SGMT  CRS-TOP  CRS-TIP   LENGTH  ELEMENTS
  1       1        1      12.15      3 
  2       1        1      18.225     1 
  3       1        1      20.25      1 
  4       2        2      12.15      3 
  5       2        2      18.225     1 
  6       2        2      10.125     1 

 ****************** PILE GEOMETRY SECTION
C   NGEN = 0   PILE HEAD AND TIP COORDS GIVEN AS (X1,Y1,Z1) AND (X2,Y2,Z2)
C   NGEN = N   GENERATE PRESENT PILE FROM PILE 'N' AS SPECIFIED BY 'NSYM' CODE
C   NSYM = 0   PRESENT PILE COORDS = PILE 'N' COORDS + (X1,Y1)
C   NSYM = 1   SYMMETRY W.R.T. GLOBAL XZ-PLANE  (X1,Y1,...,Z2) NOT USED
C   NSYM = 2   SYMMETRY W.R.T. GLOBAL YZ-PLANE  (X1,Y1,...,Z2) NOT USED
C   OMITTED PILES ARE GENERATED BY LINEAR INTERPOLATION , NGEN=0 REQUIRED
 PILE NGEN NSYM   X1-Y1-Z1-(PILE HEAD COORDS)    X2-Y2-Z2-(PILE TIP COORDS)
   1   0    0     0.0   0.0   0.0               -5.6  -5.6   50.002
   2   0    0     0.0  20.0   0.0               -5.6  25.6   50.002
   3   0    0    20.0  20.0   0.0               25.6  25.6   50.002
   4   0    0    20.0   0.0   0.0               25.6  -5.6   50.002
   5   0    0    -2.5  -2.5   0.0               -6.98 -6.98  40.001
   6   0    0    -2.5  22.5   0.0               -6.98 26.98  40.001
   7   0    0    22.5  22.5   0.0               26.98 26.98  40.001
   8   0    0    22.5  -2.5   0.0               26.98 -6.98  40.001
   9   0    0     0.0   0.0   0.0                0.0   0.0    0.0
  10   0    0     0.0  20.0   0.0                0.0   0.0    0.0
  11   0    0    20.0  20.0   0.0                0.0   0.0    0.0
  12   0    0    20.0   0.0   0.0                0.0   0.0    0.0
C   INCLUDE ALL PILES WITH 'NGEN'=0 IN BELOW TABLE
C   DUMMY PILES HAVE ZERO SEGMENTS
 PILE  SEGMENTS  SEGMENT.NUMBERS.STARTING.AT.PILE.HEAD
   1     3        1 2 3
   2     3        1 2 3
   3     3        1 2 3
   4     3        1 2 3
   5     3        4 5 6 
   6     3        4 5 6 
   7     3        4 5 6 
   8     3        4 5 6 
   9     0
  10     0
  11     0
  12     0
C   LINES ARE READ FROM BELOW TABLE UNTIL PILE2 = NUMPIL
 PILE1 PILE2  TIP-CODE  FIXED-TO
   1     1      -4         9
   2     2      -4        10
   3     3      -4        11
   4     4      -4        12
   5     5      -4         9
   6     6      -4        10
   7     7      -4        11
   8     8      -4        12
   9    12       0         0

 ****************** SPECIAL PILE NODE VALUES SECTION
C    CODE : 1   GIVEN VALUES ARE SPRING STIFFNESSES
C    CODE : 2   GIVEN VALUES ARE NODAL POINT FORCES
C    CODE : 3   GIVEN VALUES ARE SPRING SUPPORT OR SOIL DISPLACEMENTS
C    CODE : 4   GIVEN VALUE X IS TEMPERATURE CHANGE AT NODE (DEGR CENTIGRADE)
C  LINES ARE READ FROM BELOW TABLE UNTIL LINE WITH ONLY ZEROES IS FOUND
 PILE1  PILE2  NODE1  NODE2    CODE   VALUES X-Y-Z-XX-YY-ZZ
   0      0      0      0        0    0 0 0 0 0 0

 ****************** LOAD VECTOR SECTION
 SINGLE PILE FORCES AND MOMENTS ARE :  
    0     NUMPLV    NUMBER OF PILES FOR WHICH LOAD VALUES ARE GIVEN BELOW
   1.0    FACTOR    LOAD FACTOR ON BELOW FORCES AND MOMENTS
 PILE   X-FORCE  Y-FORCE  Z-FORCE   XX-MOMENT  YY-MOMENT  ZZ-MOMENT
END OF PILGEN INPUT FILE 